抽水馬達、抽水泵浦 更換

Tap water from water company and the pressure is powerful in my living area, pressure is big enough to push water into the water tank on 5th floor.

Unfortunately the water pressure was not as strong as usual last Sunday, couple of neighbors ran out of water of their water tank and found the water pressure was low, and then they turned on the water pump at home, the miserable thing was a lot of pumps didn’t work since they didn’t turn on for years included mine.

Water company had a notice on their web, it would take 4 days to fix the lower water pressure problem, of course I needed a new pump as well otherwise running out of water would happen to me soon.

Bought a stainless steel pump and replaced it, and found the previous pump was made of cast iron, it rusted seriously inside and it’s disgusting because the rusted pump was part of the pipeline at home.

我們住的是個透天的小社區,從自來水廠進來的水,原則上水壓很足夠,足夠到水都能自動補充到5樓的水塔裡,因此,每戶家裡的抽水馬達,就像是雞肋一樣,基本上用處不大,甚至應該是說,多數都已多年沒運轉了。幾年前搬來,早期的社區主委告知,我們住家裡的抽水馬達,曾經在某颱風來的時候,因停水的關係,馬達持續空轉,所以很多人家裡的抽水馬達都掛了,他建議我把電源關掉,有需要抽水的時候,再把電源打開就好,這是人家的經驗談,我一點都不想鐵齒,當然是照做了。

上星期天,有住戶說好像水壓降低,無法自行補充水塔的水,趕緊去觀察一下,還真是原本足夠的水壓,無預警的降低了不少,但水還是有的,有些住戶水塔的水先用完,因此,平常冷清沒人發言的社區群組,突然熱鬧了起來,當然都是在詢問有沒有停水、抽水馬達是否壞了、馬達開關在哪裡、啥時水壓會正常、家中的抽水馬達要轉不轉的… 該怎麼辦?住戶中抽水馬達是好的,當然就沒有水塔沒進水而造成室內沒水的問題,也有住戶隔天就找人來換新抽水馬達,然後告知他們水塔的水也已補滿了。

隔天上自來水廠網站查詢,有公告因不明原因水壓降低、正查修中,當天晚上這訊息不見了,以為已經修好了,但水壓還是低,不過還是有水的,沒想到,再晚一點居然出現了另外的公告,不明原因水壓降低查修中,且前後要4天的時間,如果真的要這麼久,那這下子我也會挫塞(嗯,如果沒水那還真是無法安心的挫塞咧),因為家中的抽水馬達也掛了。

原本要找人來換新抽水馬達,上網爬文並了解一下抽水馬達、抽水泵浦的機型和價錢,原來DIY換裝這東西不難,想想如果4天水壓不足,水無法自己流進水塔,也沒抽水馬達把水抽進水塔裡,那我絕對會面臨家中沒水的情況,確定要買的機型和自己有能力DIY後,隔天趕緊去抱了一台回家,立刻施工換裝。

新機裝好了,也順利運轉把水塔的水補滿,真爽,這樣不光只是不怕沒水,主要也還有DIY的爽度無價。沒想到再隔一天,水壓就恢復正常。我們有個鄰居建議大家,把抽水機的總電源開關持續開啟,讓抽水機能在水塔水位降低時,浮筒電門開關開啟後讓馬達運轉然後抽水,這樣馬達才不會都沒機會運轉而故障。

這次DIY的經驗得知,水塔的進水管路有個控制進水的浮球開關,構造跟抽水馬桶浮球進水開關是差不多的,所以只要水塔水位降低一些些,那個浮球就會降低一些些,進水口也會打開一些些,只要水壓夠強,就會開始自動慢慢進水,直到把水塔的水補滿。控制抽水馬達的浮筒電門開關,一定要水位下降到一定的程度,才有足夠的重力往下拉,把水位開關打開連通電路,這樣才能啟動抽水馬達。所以說,在水壓強到能把水直接推進水塔的狀況下,抽水馬達是完全沒機會因水位下降一點點就啟動的。

原本在塑鋼和不鏽鋼泵浦本體中選擇,後來還是選擇價位較高的不鏽鋼本體,換裝好運轉了一次,隔天水壓恢復正常後,它就再也沒有太大用處了。不過卻因為這次自己換裝新抽水泵浦,才發現鑄鐵做的泵浦內部嚴重生鏽,驚訝的是每天使用的自來水,居然經過有一段可怕的管路,也才知道用了好幾年的鏽水,噁!!!

『泵』浦的發音是『bon』、『ㄅㄥˋ』。

~~

▼在買新抽水泵浦之前先看一下原本舊機規格,這裡的進水管有開關,所以不用去水錶那裡關水

 

▼在打開抽水馬達上的電線盒之前,記得第一件事是先去把電源關掉嘿…

 

▼對電路的部份不了解,不過馬達上的電線盒蓋背面,有很清楚的接線說明。110V的配線,一條電源線(白色)接一條T線(黃色)、U線連接另一條黃T線、3線和4線連接另一條電源線(黑色)、1號線和2號線連接在一起。那2條黃色T線,其實是泵浦前端缺水溫控開關,一旦沒水空轉,泵浦的溫度超過溫控開關設定的溫度,就會自動斷電。所以如果不裝溫控開關,就只要白色的那條電源線直接接上U線上就可以,看完了這接線,嗯,DIY換裝抽水泵浦應該沒問題了!

 

▼就算是對電不了解,只要能依照電線箱蓋背面說明,照本宣科把幾號電線接上幾號電線就行,夠簡單吧!馬達上的每條電線,都有清楚明確的編號…

 

▼把馬達扇葉保護蓋打開,試著用手轉動馬達,它真的卡死了…

 

▼量一下管徑,2.54公分就是一英吋

 

▼原本抽水馬達規格,主要是1/2HP、110V/220V共用、口徑是3/4英吋或1英吋,剛量過是用1英吋的水管

 

▼原本在塑鋼泵浦和不鏽鋼泵浦中選擇,後來選了1/2HP中價格算是高的不鏽鋼泵浦+東元馬達

 

▼原本的接線讓銅絲有外露現象,這當然要自己把它整理好。原本也想再花一點點錢加裝泵浦溫控開關,可惜老闆不在,店員一付外行的模樣且懶懶散散、愛賣不賣的,考量自身的使用狀況,好像也不怎麼需要這溫控開關,索性就不裝了,付了錢趕緊把這東西抱回家,快快裝好趕緊抽水比較實際…

 

▼電線箱蓋背面也一樣有很清楚的接線說明,也是110V/220V共用,電線也都有標上號碼,所以只要看圖說故事,把電線接好即可,讚!

 

▼馬達上的規格表也很清楚說明配線的接法,原先的設定是110V,所以褐/黃兩條線在出廠時就已接好

 

▼買的這台是不鏽鋼泵浦本體+銅製葉輪。其實也有不鏽鋼葉輪的版本,價格會再高一些些,當時買的時候沒特別注意葉輪的材質,等裝好後再上網爬文,才清楚有不鏽鋼版本的葉輪,不過銅葉輪也沒關係啦,基本上葉輪好像多是銅製的,重點是泵浦本體材質要不生鏽的…

 

▼準備上工更換囉…

 

▼不知道為什麼附了3份一樣的說明書,難道是可以收集說明書去兌換贈品嗎?

 

▼在裝新機之前,屎尿、龜毛又GY的個性又起來,先去用水沖沖泵浦內部吧,就怕有殘留機械加工潤滑油之類的東西…

 

▼把入水開關關上,注水塞慢慢打開,藍色箭頭泵浦注水塞千萬不能一口氣就把它打開哩,否則水會突然大量噴出,那就真的挫塞了…

 

▼在把舊泵浦和水管殘水放完的等待時間,來做做手工藝吧,需要把法蘭密封橡皮中間剪開,這東西要自己剪,實在是讓人有點不爽…

 

▼嗯,像是狗啃的一樣…

 

▼水總算都放完不會噴出來了…

 

▼12mm板手拆法蘭固定螺絲

 

▼把螺絲都卸下後,搞了5分鐘才把舊泵浦和兩端法蘭 & 水管分離,因為它們實在是黏太緊了…

 

▼水管內可怕又恐怖的模樣…

 

▼法蘭+水管內緣挖出來的怪東西,這都是鐵銹咧…

 

▼螺賴吧把那些鐵銹的髒東西儘量挖除後,再用砂紙把水管和法蘭交接處磨平

 

▼搞了好一陣子,管內還是有些髒哩… 這真的是我每天用的水都會經過的管路嗎?唉…

 

▼先2顆螺絲暫時含著,連接在水管上的舊法蘭和新機的法蘭100%相符,水管上的法蘭沿用舊的就好,不用換新,爽!且馬達高度這些都不用調整,真是太幸運了,可惜…

 

▼可惜… 底座固定孔和舊機不同,需鑽新孔…

 

▼重點是有一顆馬達固定螺絲落在底座的彎角處,無法裝,所以只能鎖3顆螺絲來固定馬達,這違背了自己屎尿、龜毛又GY的個性,但又能怎麼樣呢?只好稍微安慰自己,數學上不是有不共線的3點成一個平面嗎?這…還真是個爛理由咧!!!

 

▼另外,馬達風扇護蓋有3顆螺絲,馬達裝好後3號螺絲貼近牆壁,到時候如果要把風扇護蓋打開,用手去轉轉馬達是否卡死,那非得把整個泵浦拆下,才能有足夠空間轉開這顆3號螺絲,所以囉,為了將來的幸福著想,馬達風扇護蓋3號螺絲就不裝了,這顆螺絲不裝,不會有影響…

 

▼裝新機、進出水兩端法蘭固定、螺絲鎖好,馬達風扇護蓋就鎖1、2號螺絲。在鎖法蘭左右2顆螺絲的時候,一定要兩邊平衡咧,千萬不能顧此失彼一邊鎖緊後再鎖另一邊,這樣有很大的機率會漏水,一定要一步一步2邊平衡把它們鎖緊…

 

▼看圖說故事把電線和電源接好,其實真的很簡單…

 

▼裝到這裡好像有點後悔,電源線似乎應該要伸入這電線盒裡再接上,但電線盒的空間似乎又太小…

 

▼雖然屎尿、龜毛又GY的個性又差一點要起來,想把電源線伸入電線盒再重接,想想還是算了,反正抽水泵浦安裝在室內,不會有風吹雨打日曬的問題。把接線頭用電火布包好後,還是杞人憂天的GY了一下,用束線帶把電火布束緊…

 

▼再用束線帶把電源線固定在底座上,固定馬達的底座是塑膠製品,所以也方便鑽新的固定孔…

 

▼裝好後把電源打開,馬達沒轉,只好爬上水塔把重垂開關拉一下,抽水馬達立即運轉,看到水塔開始大量進水,爽!!!

 

▼藍色箭頭進水浮球開關(跟馬桶浮球進水開關的構造類似),它稍微下降一點點且只要水壓夠強,開關就會開一點點而一點點的自動補水。兩個紅色箭頭的圓柱狀浮球(也是重力球)是抽水泵浦的電門開關,水位要下降到一定的程度,才能有足夠的重力往下拉,才能把開關連接,然後啟動抽水馬達進水。在水壓夠強的狀況下,藍色箭頭那個浮球水路開關永遠比紅色箭頭的電門開關靈敏且快速多!

 

▼手賤的把舊機泵浦本體拆開,看到這驚人的景象!!!

 

▼鑄鐵做的泵浦幾年後的狀況,每天使用的水都會經過這裡再上水塔,可怕吧???

 

▼泵浦連接進出水法蘭兩端的管路內,也是鏽得亂七八糟…

 

▼一堆鑄鐵鏽蝕脫落的殘骸把葉輪卡死,就算馬達沒壞,也一樣不會轉…

 

▼就算葉輪常常旋轉沒卡死,鑄鐵泵浦本體內部,幾年後也一樣是嚴重生鏽吧!

 

▼把馬達也拆了,這東西拿去資源回收,應該還能賣些錢吧…

 

▼我喜歡看構造圖,多少了解些相關機械類的基本結構

後記:

我們社區有好幾戶換新的抽水泵浦,都是叫維護社區機電的人來換(我們社區機電設備超單純,所以維護也很簡單),剛好那天他們來每月社區例行性檢查,那幾戶就順便請他們換新機,接連換了2天咧,生意真不錯。看到他們買來的新機,和原本建商裝的是一模一樣的,問了一下管理員,機電來裝新機的報價是多少,查了一下,讓我超驚訝的是,換裝一台收取的工錢,可以買台新機還有剩餘咧,想想這一小時可能是上千元的工資,唉,我們錢賺得少,所以還是花點時間自己動手吧!

隔壁鄰居問,不知道換裝和建商一樣的抽水泵浦好不好?我說我不是專家,好不好我不知道,但從正常的邏輯來說,如果泵浦本體是鑄鐵做的,幾年後(搞不好幾個月後就生鏽嚴重也不一定)不就發生跟現在一模一樣的狀況,然後又請人來換裝一樣會生鏽的泵浦,幾年後又發生同樣的狀況,相同的場景就這樣無止盡的輪迴,這樣好嗎?

如果有換新抽水馬達、抽水泵浦或加壓馬達、加壓泵浦這類東西的需求,尤其是家庭、民生用水,建議選擇泵浦本體是塑鋼或不鏽鋼的機型,價格也只多一些些,但卻不會像鑄鐵泵浦本體會生鏽,甚至是嚴重生鏽,因為這一裝下去,只要沒壞也就不會沒事換新機,如果每天使用、甚至飲用的水,點點滴滴都會經過嚴重生鏽的泵浦水路,這樣的水,喝起來豈不讓人膽戰心驚?

至於葉輪的材質,個人認為無論是銅或是不鏽鋼,應該都沒問題,看了一下拆開的舊機,就算是鑄鐵做的泵浦本體,裡面的葉輪也是銅做的,銅葉輪頂多在表面產生一層氧化層而已,不會像鑄鐵那樣嚴重生鏽,鏽蝕的部份脫落跑進水管,有可能阻塞管路讓水龍頭流出來的水量變小,且銅有殺菌功能,所以葉輪是銅質的應該還好。

每天喝流過那個內部嚴重生鏽泵浦的水,已好幾年的時間,只能安慰自己,或許就不會缺鐵了吧!幸好飲用水的水龍頭有裝濾水器,那些微細的鐵銹殘骸,被吞下肚的機會應該不會太多吧!

https://wp.me/p1oBFz-23L

-Eric

 

 

 

About 2266小鄭

Eric 一個中年男子小鄭 2266 的 543 生活事
本篇發表於 2018, 生活有感..., 維修, DIY, 雜項, 分享記事。將永久鏈結加入書籤。

8 Responses to 抽水馬達、抽水泵浦 更換

  1. FangDi 說道:

    前陣子也是公寓沒水,但是沒人知道問題在哪裡,而且又剛好在假日發生,水電也沒人會來,像說先去頂樓看看,那時想說先把電源關掉,看看馬達能不能用手轉,但是找半天找不到電源,只好先不看馬達,畢竟電源部分也是用電火布纏繞在電源上,弄不好水噴出來被電到可能就變成冤魂,哈哈哈哈

    所以就改從水塔上面看看浮水開關有沒有卡住,但是天殺的頂樓加蓋左右都被蓋起來,只能從窗戶爬出公園外面,在踩焊在頂樓加蓋旁的梯子才爬的上去,那時看了一下,真的重心不穩,就是真的從五樓摔下去了,不過還是這樣慢慢往上爬,但是最火大的是我需要走在類似保麗龍的屋頂,踩找看看是不是走在鋼樑上,如果踩錯也是屋頂破掉掉下去,走了幾步只能放棄往回走,等週一水電來,性命還是比較重要。

    只能說如果可以自己住一棟,有問題的時候處理起來還真的是開心又幸福,至少不用忍受那些可惡的頂樓加蓋,寄檢舉信給政府,得到的回應卻是非優先拆遷戶,會等優先拆遷拆完後才開始處理非優先拆遷戶…我看應該也得等到都更後那些頂樓加蓋才會消失吧…

    • 2266小鄭 說道:

      我們許多家中設施的裝設,其實對後續保養維修都非常不友善,就裝好、弄好、應付業主的需求,後續怎麼樣,反正都不關一開始裝機的人的問題,像是冷氣和水塔…這類東西。

      我這裡原先屋主裝潢,冷氣室外機就裝在遮雨棚的上面,現在要清潔保養室外機,就讓人頭痛了,對保養維修冷氣的人來說,非常不友善。我們隔壁當初設計裝置冷氣,就聰明的未雨綢繆,把室外機裝在遮雨棚下面,他們要清潔保養維修就很方便。在我們這裡做這些維修人員,有時為了賺錢,就得拿命來賭,實在是很糟糕,這類的從業人員,有可能會裝機,也有可能會保養維修舊機,基本上似乎不會有太多人,願意稍微想一下,或許調整一下裝新機的方式,讓後續維修保養就會方便許多!自己住一棟的最大問題是,什麼事都要自己來,或是都要自己去找人來處理。

      最近公共電視星期二晚上10點播出農村的遠見,尤其是對上星期的第二集,介紹德國懷楊鄉 Weyarn遠見懷楊,實在讓人驚歎,難怪高水準的國民素質造就高水準的國家,他們或許個人不那麼聰明,但人家集思廣益把制度規則設立好後,大家遵守這些規定,讓良好的制度成為槓桿,發揮它1+1大於2的效果和力量。我們這裡剛好相反,每個人似乎都很聰明,所以誰也不服誰,一旦設立了個制度出來後,有關係找關係,沒關係想辦法找關係,想盡辦法鑽這制度的漏洞,反正只要自己好、自己方便、自己爽就好,別人死活,關我啥事,再加上許多不公不義的司法制度和判決,很快的一個制度就崩壞了。

      依照目前看得到檯面上的這些政治人物,再加上無功有賞、打破不用賠、沒有績效考核、無淘汰退場機制、然後還可以爽爽領到死的國家員工制度,還有太多眼睛一點都不雪亮的選民,這國家會越來越好,那真是天方夜譚…

  2. 匿名 說道:

    您好:我也是在2019年中時更換不鏽鋼葉輪的泵浦.心得跟您一樣!!!喝點鏽水.不缺鐵來安慰自己!!!呵呵呵

  3. 匿名 說道:

    您好:謝謝分享,讓我獲益良多.想請教您水塔滿水後馬達自動停止的接電配置.也就是說水塔滿水後的斷電電線與抽水馬達機體的接線要如何接,這樣水塔滿水後即自動斷電停止抽水.謝謝您

    • 2266小鄭 說道:

      兄好,小弟在更換抽水馬達的時候,沒去動過任何線路哩,水塔上的滿水斷電開關線路,是原先舊馬達就已安裝好,電線也都是已拉好的,這次只是單純的換抽水馬達而已,如果將來不小心滿水斷電開關故障,也只要將這開關換掉就好。小弟家中的配置,原理上應該是很簡單,就在電源總開關抽水馬達那裡的線路上,牽一條電線連接水塔的滿水斷電開關而已,建議搜尋『抽水馬達 浮球開關』也能找到許多,以上給您參考!

  4. 優優夫 說道:

    在抽水前方加上三支20吋小胖濾心,兩道5um,一道活性碳,濾過再經抽水馬達上水塔,定期半年換一次濾芯,可以用粉久~

發表留言